Data Dictionary
Every field in the Data API data model, with JSON types, units, allowed values, and the plan tier that unlocks it.
What this dictionary covers
Every field the Data API returns or accepts, with its JSON type, unit, and the plan that unlocks it. Use it when mapping responses into your own schema, checking a unit before a calculation, or confirming which fields a plan tier includes.
Airframe core fields and usage fields come with every plan, Explorer included. Everything else needs Builder or higher.
| What you can read | Explorer | Builder, Operator, Fleet License |
|---|---|---|
| Airframe core fields | Included | Included |
| Usage fields | Included | Included |
| Airframe Builder+ fields and full camera arrays | Not included | Included |
GET /airframes/{id}/performance and POST /performance | Not included | Included |
GET /rates, GET /rates/job-types, GET /rates/metros | Not included | Included |
GET /v1/usage tells you which tier your key got: hardware_index_fields reads full on Builder and above, and Explorer keys read the core fields only. A request for a dataset outside your plan returns 403 not_in_plan, with error.plan naming your plan.
Datasets at a glance
Each dataset ships with its own snapshot date. Check that date when you cache responses or compare a figure against an outside source.
| Dataset | What it holds | Snapshot |
|---|---|---|
hardware_index | 98 airframes from 29 manufacturers, with 130 cameras and payloads | 2026-11-06 |
service_rates | 13 job types across 100 US metros plus a national benchmark | 2026-11-03 |
field_performance | Derived flight, capture, and storage figures | 2026-11-06, model version dce-engine-2026-11 |
The hardware index covers airframes released from 2016 to 2025, with take-off weights from 115 g to 28,700 g.
Airframe core fields
Every airframe record carries these fields on every plan.
Identity
Slug used in the airframe page URL (airpixels.com/drones/<id>).
Airframe maker, for example DJI.
Model name. Includes the payload where the payload defines the airframe, for example Matrice 350 RTK + Zenmuse P1.
Manufacturer and model joined for display.
Airframe class code. See airframe classes for the eight codes.
Human-readable label for the class code.
Year the airframe was released.
true for the 4 airframes no longer sold new. Discontinued airframes stay in the index because they are still flown commercially.
Physical and flight specs
Take-off weight in grams.
Maximum flight time in minutes, as published by the manufacturer.
Hover time in minutes, as published by the manufacturer.
Maximum speed in metres per second.
Maximum speed in miles per hour.
Rated maximum wind resistance in metres per second.
Rated maximum wind resistance in miles per hour.
Primary camera sensor format, for example 4/3" CMOS.
Primary camera stills resolution in megapixels.
Number of cameras or payload options listed for the airframe.
true when any available camera is thermal.
true when any available camera has a mechanical (global) shutter. This removes the rolling-shutter speed cap in performance responses.
true when the airframe supports RTK positioning.
Regulatory and commercial
US operating tier code. One of sub250_cat1, sub250, over250, over55lb. See FAA tiers.
Human-readable label for the tier code.
List price in USD for the drone plus one battery.
Field-ready kit price in USD: base price plus three extra batteries, a charging hub, and an ND filter set.
Air Pixels page for the airframe. 75 airframes have their own page; for the other 23 (FPV, fixed-wing and VTOL, legacy), the URL opens the comparison engine filtered to that model.
Provenance
true when some specs are estimates not yet checked against a published source. 82 of the 98 airframes are currently in this state.
Date the record was confirmed against a published source, or null while specs_estimated is true. The 16 verified airframes carry 2026-11-06.
Where the specs come from.
How the record was produced or checked.
Dataset snapshot date for the record.
Airframe Builder+ fields
Builder and above add the operational detail you need for kit planning, site risk assessment, and integration decisions.
Flight battery capacity in watt-hours.
Charge time in minutes.
Rated battery cycle count.
Video transmission range in kilometres, as published by the manufacturer.
Number of directions with obstacle sensing, from 0 to 6. 6 is omnidirectional.
true when a developer SDK is available for the airframe.
Ingress protection rating such as IP55, or null when the manufacturer publishes none.
true when prop guards are available or built in. This decides Category 1 eligibility for airframes under 250 g.
Price of an extra battery in USD.
Price of a charging hub in USD.
Price of an ND filter set in USD.
Kit cost as a percentage over the base price.
Impact speed in metres per second, capped at 16 m/s. Used to derive impact energy.
Impact energy in joules, computed as one half of mass times impact speed squared.
Impact energy in foot-pounds.
Camera and payload options for the airframe. See camera fields for the object shape.
Camera fields
Each entry in cameras describes one camera or payload option. The primary camera is the one every score and performance calculation uses.
Position in the array. Pass this value as camera in performance requests.
Camera name, for example 70mm 3x Medium Tele or Thermal 640x512.
true for the primary camera. Scores always use it.
true for a thermal sensor.
Sensor description, for example 1" CMOS or Uncooled VOx 12 um.
Sensor width in millimetres.
Sensor height in millimetres.
Still resolution in megapixels.
Image width in pixels.
Image height in pixels.
Actual focal length in millimetres.
35 mm equivalent focal length in millimetres.
Widest aperture as an f-number.
true when the aperture is adjustable.
true when the camera has a mechanical shutter.
Fastest interval between stills, in seconds.
Maximum video bitrate in megabits per second.
Video bit depth: 8, 10, or 12.
true when the camera records a log profile.
true when the camera records ProRes.
true when the camera records raw video.
Pixel pitch in micrometres, computed as sensor width divided by image width.
Low-light capability from 0 to 100, derived from sensor area, aperture, and pixel pitch.
Service rate fields
Each record is one job type in one market. The national benchmark uses us as the metro and a null state.
Record identifier in the form job_type:metro, for example roof-inspection:austin-tx.
Job type slug. See job types for all 13.
Human-readable job name.
Metro slug, or us for the national benchmark.
Metro display name.
Two-letter state code, or null for the national benchmark.
Price multiplier for the metro, where 1.00 is the US benchmark. Metros range from 0.84 (McAllen) to 1.32 (San Jose and the SF Bay Area).
Scope the rates cover, for example 2,500 sq ft - Residential listing.
Reference quantity for the quoted package.
Unit for the quantity: sq ft, acres, hours, piles, structures, properties, or kW.
Low rate in USD: a pilot under two years with a consumer drone and 1 million USD liability cover.
Typical rate in USD for an established operator.
High rate in USD: specialist crews, enterprise sensors, RTK or thermal, 2 million USD or more cover, and reporting.
How the rate is charged, for example Flat per listing.
Rates at each size anchor, priced at this metro's market index. See size tier fields.
Benchmark date for the record.
URL of the underlying source.
How the benchmark was produced.
Size tier fields
Size anchor quantity, in the unit given by quantity_unit.
Display label for the tier, for example 2,500 sq ft.
Low rate at this size, in USD.
Typical rate at this size, in USD.
High rate at this size, in USD.
Performance request fields
Nine mission conditions plus a camera selection. Send only the conditions that differ from the defaults; everything else falls back.
Wind speed in mph. Default 15, range 0 to 30.
Air temperature in degrees Fahrenheit. Default 68, range 15 to 105.
Site elevation in feet. Default 500, range 0 to 12,000.
Battery reserve to hold back, in percent. Default 20, range 15 to 35.
Flight altitude above ground level in feet. Default 200, range 50 to 400.
Front overlap for mapping missions, in percent. Default 75, range 60 to 85.
Side overlap for mapping missions, in percent. Default 70, range 60 to 80.
Mission speed in mph. Default 15, range 5 to 30.
Shutter speed as the denominator of 1/x seconds. Default 1000.
2505001000160020004000Index of the camera to model, matching cameras[].index. Default 0, range 0 to 9.
Performance response fields
Flight time
Expected flight time in minutes after applying the wind, temperature, and elevation factors.
Flight time in minutes available for the mission once the reserve is deducted.
Minutes lost against the brochure figure.
Flight time multiplier from wind, from 0 to 1.
Flight time multiplier from temperature, from 0 to 1.
Flight time multiplier from elevation, from 0 to 1.
true when the requested wind exceeds the airframe's rated limit.
Rated wind limit for the airframe in mph, so you can show the headroom.
Coverage and geometry
Mission radius in kilometres.
Mission radius in miles.
Ground sample distance in centimetres per pixel.
Ground sample distance in inches per pixel.
Single image footprint width in feet.
Single image footprint height in feet.
Mapping coverage per battery in acres.
Mapping coverage per battery in hectares.
Stills captured per battery at the requested overlaps.
Speed limits
Object holding the binding speeds for the mission. See the nested fields below.
Speed you asked for, in mph.
Fastest speed in mph that still holds the requested photo interval.
Fastest speed in mph that keeps motion blur acceptable at the requested shutter.
Fastest speed in mph before rolling shutter distorts the image. null when the camera has a mechanical shutter.
Speed the mission actually runs at, in mph, after applying the binding limit.
Which limit bound the speed: the requested speed, the photo interval, motion blur, or the rolling shutter cap.
true when the requested speed is above 8 m/s (about 17.9 mph) on a rolling-shutter camera.
Video and storage
Video bitrate in megabits per second for the selected camera.
Storage consumed per minute of video, in gigabytes.
Storage consumed per battery, in gigabytes.
Required card write speed in megabytes per second.
Minimum SD card class that sustains the write speed.
Batteries you can fly before filling a 256 GB card.
Batteries needed to keep flying without pausing to offload footage.
Field-ready kit cost in USD for the airframe.
Battery cost per flight hour in USD.
Regulatory and scores
US operating tier code for the airframe. See FAA tiers.
Human-readable label for the tier code.
Suitability ratings from 0 to 100 for the airframe. See the nested fields below.
Overall suitability.
Suitability for cinematic work.
Suitability for mapping and survey.
Suitability for inspection work.
Suitability for travel and transport.
Value for money against the field-ready kit cost.
Usage fields
One record per account per calendar month, in UTC.
Plan code: explorer, builder, operator, or fleet.
Plan display name.
Subscription status for the account.
Usage month the record covers.
API calls made this month.
Calls included in the plan. null on unlimited plans.
Calls left before the quota or hard cap is reached. null on unlimited plans.
true when calls stop at the quota instead of billing overage.
Calls made beyond the included quota.
Overage price per call in USD.
Estimated overage charge in USD for the month so far.
Spending cap set on the account, in USD.
Timestamp the quota resets: 00:00 UTC on the 1st of the next month.
Requests allowed per rate window.
Length of the rate window in seconds.
Dataset identifiers the plan can read, for example ["hardware_index", "field_performance", "service_rates"].
Field access tier on the hardware index for this key: core or full.
Prefix of the API key used for the request, for matching usage records to keys.
Enumerations
Airframe classes
Consumer camera. 20 airframes.
Prosumer cinema. 16 airframes.
Heavy-lift cinema. 7 airframes.
Enterprise mapping. 15 airframes.
Enterprise thermal. 17 airframes.
FPV and cinewhoop. 10 airframes.
Fixed-wing and VTOL. 6 airframes.
Legacy benchmark. 7 airframes.
FAA tiers
| Code | Label | What it means |
|---|---|---|
sub250_cat1 | Under 250 g, Category 1 eligible | Flies under Category 1 without prop guards |
sub250 | Under 250 g, Cat 1 needs prop guards | Category 1 requires prop guards fitted |
over250 | Over 250 g, registration + Remote ID | Registration and Remote ID required |
over55lb | Over 55 lb, Part 107 waiver | Operations need a Part 107 waiver |
Job types
The 13 slugs accepted in service rate queries and returned as job_type.
| Slug | Job |
|---|---|
real-estate | Real estate photography |
construction-progress | Construction progress |
roof-inspection | Roof inspection |
thermal-inspection | Thermal inspection |
weddings-events | Weddings and events |
mapping-survey | Mapping and survey |
cinematic-video | Cinematic video |
scan-to-bim | Scan to BIM |
stockpile-volumetrics | Stockpile volumetrics |
agriculture | Agriculture |
cell-tower-utility | Cell tower and utility |
insurance-claims | Insurance claims |
solar-inspection | Solar inspection |
Field conventions
A few rules apply across every dataset, so you can write one formatter instead of one per object.
- Units are in the field name where the value is dimensional:
_g,_mm,_ms,_mph,_ft,_km,_mi,_min,_pct,_usd,_mbps,_wh. A value named_usdis a number in USD, never a formatted string. - Rounding: minutes, distances, and GSD to 3 decimals; factors to 4; footprints to 0.1 ft; money to cents.
- Dates are ISO
YYYY-MM-DDstrings for snapshot and benchmark dates, andnullwhere a record has not been verified yet. nullmeans "not applicable or not published", which is different from0. Anip_ratingofnullis not a rating of zero, and arolling_shutter_capofnullmeans the mechanical shutter removes the cap.methodis free text describing how a record was produced. Read it before treating an estimate as a manufacturer figure.
82 of the 98 airframes carry specs_estimated: true and a verified_at of null. Check both fields before publishing a spec sheet or quoting a client, and prefer the 16 verified airframes when a number has to be defensible.